IQ8HC Microinverter
Base Model #: IQ8HC-72-M-DOM_ | Variant #: IQ8HC-72-M-DOM
IQ8 Series Microinverters can be added to existing IQ7 systems on the same IQ Gateway only in the following grid-tied
(05)
IQ8 Series Microinverters can be added to existing IQ7 systems on the same IQ Gateway only in the following grid-tied
configurations: Solar Only or Solar + Battery (IQ Battery 3T/10T and IQ Battery 5P) without backup.
IQ7 Series Microinverters cannot be added to a site with existing IQ8 Series Microinverters on the same gateway.
Mixed system of IQ7 and IQ8 will not support IQ8-specific PCS features and grid-forming capabilities.
IQ Microinverters ship with default settings that meet North America’s IEEE 1547 interconnection standard
requirements. Region-specific adjustments may be requested by an Authority Having Jurisdiction (AHJ) or utility
representative, according to the IEEE 1547 interconnection standard. Use an IQ Gateway to make these changes
during installation.
Meets UL 1741 only when installed with IQ System Controller 2 or 3.
IQ8 and IQ8+ support split-phase, 240 V installations only